Types & Configurations
Impingement (splash) baffle
A plate set in front of a side inlet so the incoming jet hits it and spreads, instead of blasting directly into the bed or the vessel wall.
Feed pipe with distribution holes
A pipe inside the column with drilled openings that releases feed along its length, spreading it across the section rather than at one point.
Tangential inlet with baffle
Used where the feed has to be degassed or partly separated on entry. The baffle controls the swirl and protects the internals downstream.
Reflux / return and reboiler-return baffles
Protect the top bed from a high-velocity reflux return and the bottom of the column from vapour or two-phase reboiler return impingement.
Specifications
| Parameter | Detail |
|---|---|
| Type | Impingement baffle, perforated feed pipe, tangential inlet, return baffle |
| Materials | SS304, SS316L, duplex, carbon steel, PP, PVDF, PTFE-lined |
| Design inputs | Nozzle size, feed rate and phase, column ID, distance to bed |
| Orientation | Matched to existing nozzle; horizontal, vertical or tangential entry |
| Fixing | Welded brackets, bolted removable, or clamped to existing internals |
| Wear allowance | Thicker section at the impingement point where the feed is abrasive or two-phase |
Available Materials
SS304 · SS316L · Duplex stainless steel · Carbon steel · PP · PVDF · PTFE-lined steel
Typical Applications
- Side feed nozzles on distillation columns
- Reflux returns above the top bed
- Reboiler returns and vapour inlets
- Scrubber and quench inlets
- Revamps where a new feed point has been added
Selection & Design Notes
- Tell us the distance from the nozzle to the top of the bed. That distance decides whether a simple baffle is enough or whether a distributing pipe is needed.
- Two-phase or flashing feed is the hard case — the jet expands as it enters, so the baffle has to be sized for the flashed velocity, not the line velocity.
- Abrasive slurries and catalyst fines wear through a thin baffle quickly. Specify the service and we will increase section at the impingement zone.
- Baffles are often omitted on revamps where a nozzle is reused for a higher rate. If the duty has changed, check the inlet device with it.
- Keep the baffle removable if the column needs cleaning between runs; a welded-in plate is a permanent obstruction.
How the Options Compare
A plain impingement baffle is the cheapest protection and is adequate when the nozzle is well clear of the bed. A perforated feed pipe costs more but spreads liquid across the section, which is worth it when the feed rate is high or the bed is close. Tangential entries are chosen for phase separation reasons rather than distribution, and need a baffle to control the swirl they create.